Main Header

 

 

Meister Flow Products  
FLOW SWITCHES

DUG

Flow monitor and indicator for liquids

  • wide measuring range
  • sturdy construction
  • installation in any orientation
  • high switch accuracy


Download data sheet

for liquids (0,2 - 250 l/min)
Operating temperature max.:
100°C (opt. 160°C)
Operating pressure max.:
PN 10 bar
any orientation
any flow direction
Switch contact: Normally open or change over (optional)
Display: Sight glass
EX-proof to ATEX (optional)
UL-certified (optional)
Operation:
The flow monitors and indicators type DUG operate with the float measuring principle.

DWG

Flow monitor and indicator for liquids

  • wide measuring range
  • sturdy construction
  • high switch accuracy


Download data sheet

for liquids (0,1 - 50 l/min)
Operating temperature max.:
100°C (opt. 160°C)
Operating pressure max.:
PN 10 bar
orientation vertical
flow direction bottom to top
Switch contact: Normally open or change over (optional)
Display: Sight glass
EX-proof to ATEX (optional)
UL-certified (optional)
Operation:
The flow monitors and indicators type DWG operate with the float measuring principle.

DWG-L

Flow monitor and indicator for gases

  • wide measuring range
  • sturdy construction
  • high switch accuracy


Download data sheet

for gases (3 - 1600 Nl/min)
Operating temperature max.:
80°C
Operating pressure max.:
PN 10 bar
orientation vertical
flow direction bottom to top
Switch contact: Normally open or change over (optional)
Display: Sight glass
EX-proof to ATEX (optional)
Operation:
The flow monitors and indicators type DWG-L operate with the float measuring principle.

RVO/U

Flow monitor and indicator for liquids

  • small physical size
  • sturdy construction
  • installation in any orientation


Download data sheet

for liquids (0,005 - 150 l/min)
Operating temperature max.:
100°C (opt. 160°C)
Operating pressure max.:
RVO/U-1: PN 10 bar
RVO/U-2 / RVO/U-4: PN 16 bar
any orientation
any flow direction
Switch contact: Normally open or change over (optional)
Display: Sight glass
EX-proof to ATEX (optional)
UL-certified (optional)
Operation:
The flow monitors and indicators type RVO/U operate with the float measuring principle.

 

DUM

Flow monitor for liquids

  • wide switch range
  • sturdy construction
  • high operating pressure
  • installation in any orientation


Download data sheet

for liquids (0,2 - 250 l/min)
Operating temperature max.:
100°C (opt. 160°C)
Operating pressure max.:
PN 200 bar (brass)
PN 300 bar (st. st.)
any orientation
any flow direction
Switch contact: Normally open or change over (optional)
EX-proof to ATEX (optional)
UL-certified (optional)
Operation:
The flow monitors type DUM operate with the float measuring principle.

DUM/A

Flow monitor and indicator for liquids

  • wide measuring range
  • sturdy construction
  • high operating pressure
  • installation in any orientation


Download data sheet

for liquids (0,2 - 250 l/min)
Operating temperature max.:
100°C (opt. 160°C)
Operating pressure max.:
PN 200 bar (brass)
PN 300 bar (st. st.)
any orientation
any flow direction
Switch contact: Normally open or change over (optional)
mechanical display
EX-proof to ATEX (optional)
UL-certified (optional)
Operation:
The flow monitors and indicators type DUM/A operate with the float measuring principle.

DUM/TA

Flowmeter with analog output for liquids

  • high electromagnetic compatibility
  • installation in any orientation


Download data sheet

for liquids (0,2 - 55 l/min)
Operating temperature max.:
70°C
Operating pressure max.:
PN 200 bar (brass)
PN 300 bar (st. st.)
any orientation
any flow direction
Output: 4 - 20 mA
Output: 0 - 10 V
Operation:
The flowmeters type DUM/TA operate with the float measuring principle.

DWM

Flow monitor for liquids

  • wide switch range
  • sturdy construction
  • high operating pressure
  • high switch accuracy


Download data sheet

for liquids (0,1 - 50 l/min)
Operating temperature max.:
100°C (opt. 160°C)
Operating pressure max.:
PN 200 bar (brass)
PN 300 bar (st. st.)
orientation vertical
flow direction bottom to top
Switch contact: Normally open or change over (optional)
EX-proof to ATEX (optional)
UL-certified (optional)
Operation:
The flow monitors type DWM operate with the float measuring principle.

DWM-L

Flow monitor for gases

  • wide switch range
  • sturdy construction
  • high operating pressure
  • high switch accuracy


Download data sheet

for gases (1 - 1450 Nl/min)
Operating temperature max.:
80°C
Operating pressure max.:
PN 200 bar (brass)
PN 300 bar (st. st.)
orientation vertical
flow direction bottom to top
Switch contact: Normally open or change over (optional)
EX-proof to ATEX (optional)
Operation:

DWM/A

Flow monitor and indicator for liquids

  • wide measuring range
  • sturdy construction
  • high operating pressure
  • high switch accuracy


Download data sheet

for liquids (0,1 - 50 l/min)
Operating temperature max.:
100°C (opt. 160°C)
Operating pressure max.:
PN 200 bar (brass)
PN 300 bar (st. st.)
orientation vertical
flow direction bottom to top
Switch contact: Normally open or change over (optional)
mechanical display
EX-proof to ATEX (optional)
UL-certified (optional)
Operation:
The flow monitors and indicators type DWM/A operate with the float measuring principle.

 

FLOW SENSORS

KM 10 / 11 / 12 / 13

Flowmeter in plastic for liquids

  • wide measuring range
  • high accuracy
  • optional flow regulating
  • thread connection


Download data sheet

for liquids (1,5 - 100 l/h)
Operating temperature max.:
60°C
Operating pressure max.:
PN 10 bar
orientation vertical
flow direction bottom to top
Display: Sight glass
Operation:
The flowmeters type KM 10 to KM 13 operate with the float measuring principle.

KM 16 / 17 / 18 / 20

Flowmeter in plastic for liquids and gases

  • wide measuring range
  • materials to suit application
  • optional analog output


Download data sheet

for liquids (3 - 1500 l/h)
for gases (0,2 - 50 Nm³/h)
Operating temperature max.:
60°C - 110°C
Operating pressure max.:
dependant on operating temperature (refer to data sheet)
orientation vertical
flow direction bottom to top
Display: Sight glass
Switch contact: Normally open (optional)
Output: 4 - 20 mA (optional)
Operation:
The flowmeters type KM 16 to KM 20 operate with the float measuring principle.

KM 35

Flowmeter in plastic for liquids and gases

  • wide measuring range
  • materials to suit applications
  • optional analog output


Download data sheet

for liquids (15 - 50000 l/h)
for gases (0,6 - 1600 Nm³/h)
Operating temperature max.:
60°C - 110°C
Operating pressure max.:
dependant on operating temperature (refer to data sheet)
orientation vertical
flow direction bottom to top
Display: Sight glass
Switch contact: Normally open (optional)
Output: 4 - 20 mA (optional)
Operation:
The flowmeters type KM 35 operate with the float measuring principle.

RVP/U

Flow monitor in plastic for liquids

  • small physical size
  • sturdy construction
  • installation in any orientation


Download data sheet

for liquids (0,02 - 30 l/min)
Operating temperature max.:
50°C
Operating pressure max.:
PN 10 bar
any orientation
any flow direction
Switch contact: Normally open or change over (optional)
Operation:
The flow monitors type RVP/U operate with the float measuring principle.

 

DHGF-10

Impeller flowmeter for liquids

  • high accuracy
  • frequency output
  • installation in any orientation
  • thread connection


Download data sheet

for liquids (50 - 1000 l/h)
Operating temperature max.:
80°C
Operating pressure max.:
PN 5 bar
any orientation
any flow direction
pulse output
Operation:
The flowmeters type DHGF-10 are impeller flowmeters.

DHGF-2 / DHGF-4

Impeller flowmeter for liquids

  • high accuracy
  • frequency output
  • installation in any orientation
  • thread connection


Download data sheet

for liquids (1,5 - 250 l/h)
Operating temperature max.:
80°C
Operating pressure max.:
PN 6 bar
any orientation
any flow direction
pulse output
Operation:
The flowmeters type DHGF-2 and DHGF-4 are impeller flowmeters

DHSF-2 / DHSF-4

Impeller flowmeter for liquids

  • high accuracy
  • frequency output
  • installation in any orientation
  • hose connection


Download data sheet

for liquids (1,5 - 250 l/h)
Operating temperature max.:
80°C
Operating pressure max.:
PN 6 bar
any orientation
any flow direction
pulse output
Operation:
The flowmeters type DHSF-2 and DHSF-4 are impeller flowmeters.

DHTA-1SE / DHTA-2SE

Flowmeter for liquids

  • PP construction
  • Analog output (4 - 20 mA)
  • high accuracy


Download data sheet

for liquids (0,15 - 10 m/s)
Operating temperature max.:
80°C
Operating pressure max.:
PN 10 bar
any orientation
any flow direction
Output: 4 - 20 mA
Operation:
The flowmeters type DHTA-1SE and DHTA-2SE are impeller flowmeters.

DHTF-1

Impeller flowmeter for liquids

  • high accuracy
  • PP-Version
  • Mounting in different pipe diameters possible (mounting via T-piece)


Download data sheet

for liquids (0,15 - 10 m/s)
Operating temperature max.:
80°C
Operating pressure max.:
PN 10 bar
any orientation
any flow direction
pulse output
Operation:
The flowmeters type DHTF-1 are impeller flowmeters.

DHTF-1SE

Impeller flowmeter for liquids

  • high accuracy
  • PP-Version
  • Mounting in different pipe diameters possible (mounting via T-piece)
  • many options


Download data sheet

for liquids (0,15 - 10 m/s)
Operating temperature max.:
80°C
Operating pressure max.:
PN 10 bar
any orientation
any flow direction
pulse output
Operation:
The flowmeters type DHTF-1SE are impeller flowmeters.

DMI-V1E

Flowmeter for liquids

  • easy installation
  • installation in any orientation
  • high accuracy
  • maintenance-free


Download data sheet

for liquids (0,1 - 760 m³/h)
Operating temperature max.:
-25°C - 120°C
Operating pressure max.:
PN 16 bar
any orientation
any flow direction
digital display
Output: 4 - 20 mA
pulse output
Operation:
The flowmeters type DMI-V1E are electromagnetic flowmeters.

DMI-V2E

Flowmeter for liquids

  • easy installation
  • installation in any orientation
  • high accuracy
  • maintenance-free


Download data sheet

for liquids (0,6 - 5400 m³/h)
Operating temperature max.:
80°C (opt. 90°C)
Operating pressure max.:
PN 10 bar / PN 16 bar / PN 40 bar
dependant on nominal size
any orientation
any flow direction
digital display
Output: 4 - 20 mA
pulse output
Operation:
The flowmeters type DMI-V2E are electromagnetic flowmeters.

 

FLOW LIMITERS

MODELS :-BA / BB / BC

Flow Limiters

 

  • high reliability
  • installation in any orientation
  • suitable for hot water
  • thread connection

Meister Flow Limiters
Download data sheet

for water (1 - 390 l/min)
Operating temperature max.:
200°C
Operating pressure min.: PN 2 bar
Operating pressure max.: PN 10 bar
any orientation
any flow direction

Meister Flow Limiters

Operation:
The flow limiters work on a pure mechanical base and do not require any external power source.
The cross sectional area, available to the flowing medium, will change with pressure changes in that way, that an almost constant flow stream can be maintained.
Google